Function

With its flexible modularity providing seamless and risk-free power scalability up to 100 + 25 kW, the MODULYS GP-UL range is the ideal solution for unscheduled site upgrades or incremental power evolutions. The installed power can be increased up to 100 + 25 kW by adding hot-swap plug-in power modules for incremental steps of 25 kW.
Designed with no single point of failure, the MODULYS GP-UL offers all the advantages of the Green Power 2.0 technology.

Conformity to standards

UL1778
CSA C22.2 N. 107.3-05
FCC part15 Class A
IEC 62040-3 (VFI-SS-111)
NEMA 1 (IP20)
SEISMIC OSHPD pre-approval (available as option)

Advantages

Fully modular system

- Plug-in power module.
- Plug-in battery module.
- Plug-in auxiliary mains bypass module.
- Top or bottom connection.
- Top-air exhaust module.

‘Forever Young’ concept

- Exclusive life cycle extension program.
- Eliminates end-of-life criticality.
- Based on an electronics-free cabinet and a set of plug-in parts. 
- Module compatibility guaranteed for 20+ years.
- Allows for the implementation of future module technology.
- Company declaration of 20+ year compatibility

Totally redundant design

- N+1, N+x redundancy level.
- Designed for no single point of failure.
- No centralized parallel control.
- Totally independent power modules.
- Redundant parallel bus connection (ring configuration).

Enhanced serviceability performance

- Power module automatic firmware alignment. 
- Fast & safe maintenance based on hot-swap parts (power modules, auxiliary mains bypass, electronic boards).
- Load fully protected in online double conversion mode (VFI) during power module replacement.
- 3-color LED bar for quick and easy detection of the power module status.
- Battery can be hot-swapped without shutting down the connected equipment. 
- Ready for concurrent maintenance.

UPS ModelMODULYS GP-UL 40 KWMODULYS GP-UL 25-100 KW
Number of power modules1212345(5)
Power (Sn)25 kVA40 kVA25 kVA50 kVA75 kVA100 kVA100 kVA (N+1)
Power (Pn)25 kW40 kW25 kW50 kW75 kW100 kW100 kW (N+1)

 

Input
Voltage480 V 3ph (±15%) up to -40 @ 50% of nominal load3ph 480 V (±15%) up to -40% @ 50% of nominal load
Frequency60 Hz ± 10%
Input power factor> 0.99(1)
Total harmonic input current distortion (THDi)< 3% (@: Pn, Resistive load, Mains THDv < 1%)

 

Output
Voltage400 V 3ph+N480 V 3ph
Frequency60 Hz
Total output voltage distortion (THDv)< 1% (@ Pn, Resistive load)
Overload(2)125% for 10 minutes, 150% for 1 minute
Crest Factor> 2.7> 3.3> 2.7> 3.3

 

Static Bypass(3)
Bypass input voltagerated output voltage ± 15%
Bypass input frequency60 Hz ± 2% selectable (±8% if Genset is used)

 

Stored energy mode of operation
Number of battery blocks (VRLA)from 18+18 to 24+24

 

Environment
ModelMODULYS GP-UL 40 KWMODULYS GP-UL 25-100 KW
Operating temperature32 to 104 °F(3)(4) / 0 to +40 °C(3)(4)
Storage Temperature23 to 122 °F / -5 to +50 °C
Relative humidity95 % without condensation
Altitude (max)3,300 ft (9,840 ft. with derating) / 1,000 m (3,000m with derating)
Acoustic level at 1 m< 56 dBA< 58a dBA
Required air capacity470 CFM1178 CFM
Dissipated power (max)3,500 W @ Pn / 11,950 BTU @ Pn5,200 W @ Pn / 17,750 BTU @ Pn

 

Dimensions and weight
ModelMODULYS GP-UL 40 KWMODULYS GP-UL 25-100 KW
Dimensions (WxDxH)2’ 2" 5/8 x 2’ 2" 17/64 x 6’ 6" 5/64 676 x 895 x 1983 mm
Empty cabinet1,380 lbs / 626 kg1,043 lbs / 473 kg
UPS module75 lbs / 34 kg
Battery module220.5 lbs / 100 kgmodular battery cabinet

 

Standards
SafetyUL1778, CSA-C22.2 No. 107.3-05, MET File E114654
EMCFCC part 15 Class A
PerformanceIEC 62040-3 (VFI-SS-111)
Degree of protection standardNEMA 1 (IP20)
SEISMICOSHPD (available as option)

 

(1) Pout > 50% Sn.
(2) Initial Condition Pout < 80% Pn.
(3) The UPS is not compatible with the use of an external bypass system.
(4) The UPS is not compatible with the use of an external bypass system
(5) According to IEC 62040-3.
(6) 5th module is for redundancy.