Energy Station VERSA™
Our most versatile PDU with the most configurability
One size does not fit all. Our most versatile unit supports extensive configurability to meet unique system requirements to maximize effectiveness, and meet a wide range of data centre applications.
Brochures:
Support:

Key features of the Energy Station VERSA™:
- Size Range/Rating: 50-1000kVA
- The most configurable PDU on the market
- Class-leading, efficient OPAL™ transformers with an attractive ROI
- Supports unique system requirements
- Fitted to space requirements
- High density options
- Zero downtime equipment inspections
- Reduced arc flash risk
- Seismic certified
- Integrated web-accessible Cyberhawk™ metering options
Model | Description | Busway Applications | Traditional Applications | |
---|---|---|---|---|
VERSA | ![]() |
One size does not fit all. Our most versatile unit supports extensive configurability to meet unique system requirements and maximize effectiveness. | ![]() |
![]() |
TX | ![]() |
Transformer with integrated breakers supports an even greater overall reduced footprint and simplified deployment closer to the load. | ![]() |
![]() |
LM | ![]() |
All the benefits of a Powersmiths’ solution made to match a server cabinet look, for sleek in-row styling that brings symmetry and visual balance to row. | ![]() |
![]() |
MVO | ![]() |
One unit doing the work of many. Dual and triple voltage outputs allow 480/277V, 415/240V and 208/120V to simultaneously coexist. Also enables incremental migration for future expansion/upgrade. | ![]() |
![]() |
HID | ![]() |
Geared towards retrofit applications that require greater power densities than existing units can provide. HID supports front and rear distribution for deployment in mid-row. | ![]() |
![]() |
Compare Configuration Options for each Energy Station™ PDU Model
All PDUs come standard with OPAL™ Series transformers: Optimized efficiency for the application, with managed inrush currents.
Energy Station™ Configuration Options | VERSA | LM | MVO | HID | TX |
---|---|---|---|---|---|
Size Range/Rating | 50-1000kVA | 75-375kVA | 50-1000kVA | 300-1000kVA | 50-1500kVA |
Engineered Impedance and Short Circuit Currents | ![]() |
![]() |
![]() |
![]() |
![]() |
Input: Dual Source, Kirk Key, Maintenance Bypass, etc. | ![]() |
n/a | ![]() |
![]() |
n/a |
Multi Voltages: 208/120V, 415/240V, 480/277V | ![]() |
n/a | ![]() |
n/a | n/a |
Dual Voltage Outputs: Voltage migration 208-415V (Future Proofing) | ![]() |
n/a | ![]() |
![]() |
![]() |
Panel Boards | ![]() |
n/a | ![]() |
![]() |
n/a |
Sub-feed Breakers | 100-1200A | 250A & 400A | 100-1200A | 100-1200A | 250-1600A |
Sub-feed Plug-in Breakers | 100-400A | n/a | 100-400A | 100-400A | n/a |
Direct Busway Distribution | ![]() |
![]() |
![]() |
![]() |
![]() |
Distribution to In-rack PDUs, Direct to Servers | ![]() |
n/a | ![]() |
![]() |
n/a |
Monitoring: Main Input/Output | ![]() |
![]() |
![]() |
![]() |
![]() |
Monitoring: Sub-feed, Panel Boards | ![]() |
![]() |
![]() |
![]() |
n/a |
Protocols: Modbus TCP, BACnet/IP, http webpages | ![]() |
![]() |
![]() |
![]() |
![]() |
SPD – Surge Protection Devices | ![]() |
![]() |
![]() |
![]() |
![]() |
360º Rotatable IR Port™ with Meter Connections | ![]() |
![]() |
![]() |
![]() |
![]() |
Fixed IR Ports per Breaker Terminal | ![]() |
n/a | ![]() |
![]() |
![]() |
Arc Flash Exposure Mitigation: Compartmentalization | ![]() |
n/a | ![]() |
![]() |
![]() |
True Front-Only Access | ![]() |
Front & Rear | ![]() |
Front & Rear | ![]() |
High Density: Front/Rear | ![]() |
n/a | ![]() |
![]() |
n/a |
Application Specific Engineering | ![]() |
![]() |
![]() |
![]() |
![]() |
OSHPD & IBC Seismic Certified (Live Shake Table Test) | ![]() |
n/a | ![]() |
![]() |
n/a |
Environment: Indoor/Outdoor | ![]() |
n/a | ![]() |
n/a | ![]() |
Low Friction Positioning Rollers | ![]() |
![]() |
![]() |
![]() |
n/a |
Lifting Eyes for Overhead Crane | ![]() |
n/a | ![]() |
![]() |
n/a |
Supports for Pallet Truck Handling from Receiving to Installation | ![]() |
![]() |
![]() |
![]() |
![]() |
= Option applies to model n/a= Option not applicable for model